TM9-2320-387-24-l 1 2-46. STE/lCE-R TEST PROCEDURES (Cont’d) I (g) Transducer Cable Conneckms J2,53. Counectors 52 or 53 connect the VTM to any transducer in the transducer kit. Operating power is supplied to the transducer and signals from the transducers are supplied to the VIM through the cable. Connectors 52 and 53 are identical and can be interchanged with each other or used in combination. (h) Test Probe Cable Connector 54. Connector 54 connects test leads to the VTM when doing manua; voltage resistance tests. SIMPLIFIED TEST EQUIPMENT/INTERNAL COMBUSTION ENGINE-REPROGRAMMABLE (STE/ICE-R SYSTEM) 2-511