TM-9-2320-387-24 HMMWV Direct Support & General Support Maintenance Manual Volume 1 Download
Page 232 of 1205
TM 9-2320-387-24-l REFERENCE INFORMATION ENGINE COOLING (I RESISTANCE AND CONTINUITY 04,500 OHMS STVICE-R TEST 91 1. Connect RED clip and BLACK clip to the terminations indicated in the question. RED to the first, BLACK to the second. 2. Start Test 91.0-4.500 Ohms. 3. Displayed reading is in ohms. Less than 5 ohms is continuity. If the resistance is over 4,500 ohms, SLUICE-R displays .9.9.9.9. Replace control valve ( para. 8 25). CONTINUITY (RESISTANCE) MULTIMETER 1. Set the voltmeter to an ohms scale of about 1,000 ohms. 2. Connect the RED and BLACK leads to the connections stated in the question. 3. Be sure to read the correct scale. Less than 5 ohms indicates continuity. For an open circuit, the meter should peg full scale (needle all the way to the left). Repair/replace wire (para. 4-80). DC VOLTAGE O-45 VOLTS STEKE-R TEST 89 1, Connect RED clip to the indicated-test point, BLACK clip to negative or ground. 2. Start Test 89. DC Volts. 3. Displayed reading is in volts. Repair/replace wire (para. 4-80). VOLTAGE MULTIMETER 1. Set me voltmeter to a DC volts scale of at least 40 volts. 2. Connect the RED lead to positive and the BLACK lead to negative. 3. Be sure to read the correct scale. I CONTROL VALVE w t_ ELECTRICAL CONNECTOR P - 5 . .-,- .’ v=i! NO STEP FAN TEMPERATURE VALVE 2-175