TM 9-2320-362-14&P 3-30. POWER INTERFACE BOX REPLACEMENT (Cont’d) b. Installation 1. 2. 3. 4. 5. 6. 7. 8. 3-68 Install power interface box (4) onto fixed rear door (31) and secure with four screws (16), washers (17), and self-locking nuts (18). Install cables as follows: (a) cable W68 (22) to terminal llE1 (21), (b) cable W70 (27) to terminal 11E2 (19), (c) cable W71 (26) to terminal 11E3 (20), and (d) secure with three washers (23), lockwashers (24), and nuts (25). Close cover (28) and secure with fastening latch (29). Route cable W69 (3) and W67 (5) through hole in enclosure panel (l). Install SHUNT end of cable W69 (3) to negative terminal (9) on shunt (10) and secure with screw (8). Install POWER STUD end of cable W67 (5) to positive terminal (12), Secure with washer (13), lockwasher (14), and nut (15). Place cable clamp (2) over cables W69 (3) and W67 (5) and secure to enclosure panel (1) with Place fixed rear door (31) against captive screw (7) and four special screw (6). side of truck (32) and secure-with bolts (30), .