TM-9-2320-362-14&P HMMWV Technical Manual Electrical Environmental System (EES) Download

Page 35 of 353

TM 9-2320-362-14&P Table 3-1. Unit Preventive Maintenance Checks and Services (Cont’d) S-Semiannually A-Annually B-Biennially ITEM INTERVAL ITEM TO BE NO. INSPECTED PROCEDURES s A B 1 POWER INTERFACE a. Inspect power cable connections BOX (Cent’d) for tightness. Tighten loose connections. b. Inspect terminals and power cables for corrosion, dirt, grease, or fungus. Clean with wire brush, wiping rags, and detergent. c. Inspect power cables for frayed, cracked, or worn insulation. Repair or replace damaged components. Install fixed rear door (4) against side of truck (3) and secure with captive screw (1) and four special bolts (5). 2 COMPRESSOR Inspect compressor for secure mounting and oil leakage. Tighten any loose mounting hardware (TM 9-2320-280-20), and report any oil leakage to DS maintenance. 3 200 AMP a. Inspect 200 amp alternator and ALTERNATOR voltage regulator for proper installation and mounting. b. Inspect electrical wiring for broken strands, frayed, cracked, or worn insulation, and loose connections. 3-5