TM-9-2320-362-14&P HMMWV Technical Manual Electrical Environmental System (EES) Download

Page 179 of 353

TM 9-2320-362-14&P 4-18. EES KIT INSTALLATION (Cont’d) dd. Freon Lines Installation 1. 2. 3. 4. 5. 6. Cut insulation (1) from suction hose (2) as follows: (a) Measure 11 in. (27.94 cm) from end of suction hose (2) and make circular cut around insulation (1). (b) Cut insulation 22 in. (55.88 cm) lengthwise. (c) Make another circular cut around insulation (1) at 33 in. (83.82 cm). Remove insulation (1) from suction hose (2). Cut insulation (4) from discharge hose (3) as follows: (a) Measure 33 in. (83.82 cm) from end of discharge hose (3) and make circular cut around insulation (4). (b) From end of discharge hose (3), cut insulation (4) lengthwise until circular cut is reached. Remove insulation (4) from discharge hose (3). Install suction hose (2) through hole (6) in transmission tunnel (5). Install discharge hose (3) through hole (6) in transmission tunnel (5). 4-67