TM-9-2320-362-14&P HMMWV Technical Manual Electrical Environmental System (EES) Download

Page 172 of 353

TM 9-2320-362-14&P 4-18. EES KIT INSTALLATION (Cont’d) w. 200 Amp Alternator Ground Strap Installation 1. 2. 3. 4. 5. NOTE Ensure terminal is clean before connection is made. Apply copper shield sparingly to bolt (8) surface of ground strap (4), Insert bolt (8) through hole in ground strap (4). Install bolt (8) and ground strap (4) to upper hole on mounting bracket (6). Tighten to 48 lb-ft (65 N·m). Remove nut (1), lockwasher (2), and lead 3B (3) from ground stud (7) on 200 amp alternator (5). Retain lockwasher (2) for installation. Install ground strap (4) and lead 3B (3) to ground stud (7) and secure with lockwasher (2) and nut (1). Tighten nut (1) to 96-144 lb-in. (11-16 N·m). 4-60