TM 9-2320-362-14&P 4-18. EES KIT INSTALLATION (Cont' d) 28. Modify front floorboard (1) as follows: (a)Turn front floorboard (1) over so underside is face up. (b) Determine center of hole (3) by measuring 4 3/8 inches (11.10 cm) down from top edge of front floorboard (3) and 2 1/2 inches (6.35 cm) from left edge of front floorboard (1). WARNING When drilling, be sure to wear goggles for eye protection or injury to personnel may occur. (c) Using 2 1/2-inchhole saw, drill hole (3) through front floorboard (1). (d) Mark 2 1/2 inches (6.35 cm) wide channel (2) from hole (3) to right edge of front floorboard (1). (c)Chisel 1/8-inch (0.30 cm) deep channel (2) from hole (3) to right edge of front floorboard (1). 4-50