TM-9-2320-362-14&P HMMWV Technical Manual Electrical Environmental System (EES) Download

Page 144 of 353

TM 9-2320-362-14&P 4-13. FREON LINES REPLACEMENT (Cont’d) 14. Place insulation (10) and (13) around suction hose (14) and discharge hose (7). Secure insulation to hoses with tie-straps (9). 15. Install lanyard (11) from large dust cap through swaging sleeve (12). Loop lanyard (11) around suction hose (14) and back through swaging sleeve (12). Crimp swaging sleeve (12). 16. Install lanyard (11) from small dust cap through swaging sleeve (12). Loop lanyard (11) around discharge hose (7) and back through swaging sleeve (12). Crimp swaging sleeve (12). 17. Connect suction hose (14) and discharge hose (7) to quick disconnects (15) and (6). 18. Install cover (4) to freon line channel (5) and secure with four screws (1), lockwashers (2), and washers (3). 4-32