TM-9-2320-362-14&P HMMWV Technical Manual Electrical Environmental System (EES) Download
Page 140 of 353
TM 9-2320-362-14&P 4-13. FREON LINES REPLACEMENT (Cont’d) b. Installation 1. 2. 3. 4. 5. 6. 7. 8. Cut insulation (1) from upper section of suction hose (2) as follows: (a) Measure 11 in. (27.94 cm) from end of suction hose (2) and make circular cut around insulation (1). (b) Cut insulation 22 in. (55.88 cm) lengthwise. (c) Make another circular cut around insulation (1) at 33 in. (83.82 cm). Remove insulation (1) from suction hose (2). Trim removed insulation (1) 3 in. (7.62 cm). Cut insulation (4) from upper section of discharge hose (3) as follows: (a) Measure 33 in. (83.82 cm) from end of discharge hose (3) and make circular cut around insulation (4). (b) From end of discharge hose (3), cut insulation lengthwise until circular cut is reached. Remove insulation (4) from discharge hose (3). Trim removed insulation (4) 3 in. (7.62 cm). Pull suction hose (2) up through hole (6) in transmission tunnel (5). Pull discharge hose (3) up through hole (6) in transmission tunnel (5). 4-28