TM-9-2320-362-14&P HMMWV Technical Manual Electrical Environmental System (EES) Download
Page 118 of 353
TM 9-2320-362-14&P 4-8. CIRCUIT BREAKER REPLACEMENT (COnt’d) 1. Install bus bar (19) on load side of circuit breaker (18) and secure with two lockwashers (22) and screws (21). 2. Install bus bar (11) on line side of circuit breaker (18) and secure with washer (10), lockwasher (9), and screw (8). 3. Install circuit breaker (18) into power interface box (4). 4. Install boot (1) and guard (2) onto power interface box (4) and secure with four washers (24), lockwashers (25), and screws (26). 5. Secure bus bar (11) to terminal 11E4 (3) with washer (15), lockwasher (16), and nut (17). 6. Secure wire assembly lead (13), bus bar (23), and bus bar (19), with washers (14), screw (12), and nut (20). 7. Install gasket (5) and cover (7) on power interface box (4) and secure with sixteen screws (6). 4-6