TM-9-2320-362-14&P HMMWV Technical Manual Electrical Environmental System (EES) Download
Page 110 of 353
TM 9-2320-362-14&P 3-32. INCANDESCENT LAMP AND LENS REPLACEMENT This task covers: a. Removal b. Installation INITIAL SETUP: Equipment Condition Circuit breaker is off 1. Remove lens (4) and O-ring (3) from power interface box (l). 2. Separate lens (4) from incandescent lamp (2). 1. Install incandescent lamp (2) into lens (4). Install lens (4) and O-ring (3) on power interface box (l). 2. FOLLOW-ON TASK: Turn on circuit breaker. 3-33. 200 AMP ALTERNATOR REPLACEMENT NOTE Refer to TM 9-2320-280-20 for replacement of the 200 amp alternator. 3-80