TM-9-2320-280-34 HMMWV Direct Support & General Support Maintenance Manual Download
Page 643 of 1258
TM 9-2320-280-34 14-10. AMBULANCE HEATER REPAIR (MODEL 10530A) (Cont’d) 5. Flame detector switch (8): (a) Remove adjusting screw (6), washer (5), and spring (11) from flame detector switch (8). (b) Remove ceramic rod (4) from tube (9). Inspect ceramic rod (4) for cracks, chips, or breakage. Replace flame detector switch (8) if ceramic rod (4) is cracked, chipped, or broken. (c) Clean flame detector switch (8) with compressed air. (d) Inspect flame detector switch (8) for damaged or defective parts. Replace flame detector switch (8) if any part is damaged or defective. (e) Carefully insert ceramic rod (4) into tube (9). Install spring (11) on channel (10), tip microswitch (7) down, and install washer (5) and adjusting screw (6). (f) Turn adjusting screw (6) clockwise until microswitch (7) just "clicks". Turn adjusting screw (6) an additional 3/4 turn clockwise, and seal screw (6) in place with insulating varnish. 14-43