TM 9-2320-280-34 6-4. 200 AMPERE ALTERNATOR (A0013036AA) TESTING AND REPAIR (Cont’d) 14. Install insulator (3) over three stator studs (2) with six spring washers (4), three washers (5) and three nuts (6). Tighten nuts (6) to 16-18 lb-ft (22-24 N m). 15. Install two brush gaskets (15) over two brush springs (16). 16. Install two brush leads (13) through brush cover (14) and diode trio panel (12) and install two brushes (21) into brush holder (17). 17. Connect two brush leads (13), lead 10 (24), lead 8 (27), and lead 11 (28) to diode trio panel (12) with three lockwashers (25) and screws (26). 18. Connect three negative rectifier leads (1) to three stator studs (2) with three nuts (7). Tighten nuts (7) to 12-14 lb-ft (16-19 N m). 19. Install O-ring (18), plate (19), and rubber gasket (20) on brush holder (17). 20. Position spacer (22) between diode trio panel (12) and brush cover (14) and retain in place by installing insulation washer (8), washer (9), lockwasher (10), and screw (11) through diode trio panel (12), spacer (22), brush cover (14) and brush holder (17). Repeat step for three remaining spacers (22). NOTE Leads #1, #2, #3, #4 and #5 should be routed through opening provided into the rectifier cavity of housing. Leads #8, #10 and #11 will be attached to the regulator and should be routed toward the outside of housing. 6-34