TM-9-2320-280-34 HMMWV Direct Support & General Support Maintenance Manual Download
Page 336 of 1258
TM 9-2320-280-34  Change 1 6-18.31  6-3.3. 100 AMPERE DUAL VOLTAGE ALTERNATOR (12447110) TESTING AND REPAIR (Cont’d)  CAUTION  Ensure auxiliary measuring equipment is properly grounded to test  stand. Failure to do so may lead to erroneous readings or damage to  equipment.  NOTE  Prior to operation of test stand, ensure all switches and controls are in  initial positions as referenced in Operator and Maintenance Manual,  TM 9-4910-663-12 (UMC Model GSAR-500), or Operator and  Maintenance Manual, TM 9-4910-485-12 (Sun Model AGT-9/9A).  6. Set test stand as follows: Model GSAR-500 Model AGT -9/9A  (a) DC ammeter load and starter selector X10 500 amp  (b) DC ammeter field and battery charge selector X1 5 amp  (c) Field circuit switch Regulator Regulator  (d) DC voltmeter circuit selector RECT/GEN RECT/GEN  (e) Connect DC voltmeter (0-50 VDC) from point between regulator 14 VDC output and load in  14-volt circuit (or 14-volt battery).  (f) Connect ammeter (0-75 ADC) in load line from 14 V regulator to 14 V load.  7. Turn test stand master power switch and master load switch to ON, and turn battery switch to  24 VDC. Green lamp on test stand must illuminate.  8. Perform no-load test. Set test stand battery circuit selector to 24 VDC, IGN switch to ON, and start  varidrive. Observing the DC voltmeter output voltage and tachometer rpm, increase speed until  tachometer reads 5000 rpm. Record voltmeter reading and refer to table 6-A.3, No-Load Test, for  diagnosis.