TM 9-2320-280-34 6-3. 60 AMPERE ALTERNATOR REPAIR (Cont’d) 18. Install O-ring (4), negative rectifier leads (13), positive rectifier leads (9), leads (20), and output plate (2) into end housing (5) with four screws (1). 19. Apply silicone compound to negative rectifier plate (17). Install negative rectifier plate (17) on end housing (5) with two washers (16) and screws (15). 20. Connect three negative rectifier leads (13) to three negative rectifier terminals (14). CAUTION Do not overheat rectifier leads when soldering to rectifier terminals. Damage to rectifiers will result. 21. Solder negative rectifier leads (13) to negative rectifier terminals (14). 22. Apply silicone compound to insulator (6), positive rectifier plate (7), and install insulator (6) and positive rectifier plate (7) on end housing (5) with three nylon washers (12), washers (11), and screws (10). 23. Connect six positive rectifier leads (9) to four positive rectifier terminals (8). 24. Solder positive rectifier leads (9) to positive rectifier terminals (8). 25. Apply insulating compound to seven rectifier terminals (8) and (14). 26. Connect lead (18) to output plate stud (3) and install tie strap (19) on four leads (20). 6-14