TM-9-2320-280-34 HMMWV Direct Support & General Support Maintenance Manual Download

Page 122 of 1258

TM 9-2320-280-34 3-22. ENGINE REMOVAL (6.2 L) (Cont’d) NOTE Disconnects for the 100 amp and 200 amp Neihoff regulators are basically the same. Differences are shown in the illustration. Perform steps 64 through 77 for vehicles equipped with Neihoff 200 amp alternator only. Prior to removal, tag leads for installation. 64. Disconnect regulator plug (13) from voltage regulator (12). 65. Slide back rubber boot (4) and remove nut (3), lead 5A (2), and washer (1) from red (energize) terminal (19). 66. Slide back rubber boot (5) and remove nut (6), lead 2A (7), and washer (8) from yellow (AC) terminal (9). 67. Remove two screws (18), lockwashers (17), and washers (16) from voltage regulator (12) and alternator (15). Discard lockwashers (17). 68. Remove capscrew (10), lockwasher (11), spacer (14), and voltage regulator (12) from alternator (15). Discard lockwasher (11). 3-60