TM 9-2320-280-34 22-16.12 Change 1 22-9.2. LEFT FRONT FLOOR PANEL REPAIR (Cont’d) 1. Position metal strip C (1), with arrow facing up and toward metal strip A (4) on insert panel (2). Align reference lines (3). 2. Using metal strip C (1) as a template, locate, mark, and drill seven 0.187-in. diameter holes in insert panel (2). Remove metal strip C (1). 3. Apply approximately 0.125-in. thickness of adhesive sealant to shaded surface of insert panel (2) and metal strip C (1). 4. Position metal strip C (1) on insert panel () and install with seven rivets (6). 5. Remove any adhesive residue and clean edges of metal strip C (1) and insert panel (2). 1. Position metal strip D (6), with arrow facing up and toward metal strip A (4), on insert panel (2). Align reference lines (7). 2. Using metal strip D (6) as a template, locate, mark, and drill seven 0.187-in. diameter holes through insert panel (2). f. Metal Strip D and Insert panel Assembly e. Metal Strip C and Insert Panel Assembly