TM 9-2320-280-34 22-16.6 Change 1 22-9.2. LEFT FRONT FLOOR PANEL REPAIR (Cont’d) 3. Cut metal strip (2) from sheet metal, and mark two reference lines (1), centerline (3), directional arrow (4), and letter B on metal strip (2). 4. Locate, mark, and drill twenty-six 0.187-in. diameter holes through metal strip B (2). 5. Cut two metal strips (5) from sheet metal, and mark centerlines (7), directional arrows (6), and letters C and D on metal strips (5). 6. Place metal strip C (5) on a suitable work surface, with arrow (6) facing up and left. 7. Locate, mark, and drill seven 0.187-in. diameter holes through metal strip C (5). 8. Place metal strip D (5) on a suitable work surface, with arrow (6) facing up and left. 9. Locate, mark, and drill fourteen 0.187-in. diameter holes through metal strip D (5).