TM 9-2320-280-20-3 Change 2 D-25 Section II. ILLUSTRATED MANUFACTURING INSTRUCTIONS (Cont'd) INSTRUCTIONS: 1. Determine cable number needed from RPSTL and cut wire 6154-00-705-6674 to length as shown. NOTE • Items 1, 4, 5, 6, and 7: flat of terminals to be 90° offset as shown without wire twist. • Item 6: one terminal end is bent 30°. 2. Select and solder proper end terminals to cable ends as shown. (Refer to TC 9-237 for soldering instructions.) NOTE Insulator boot 5582481 is installed on 30° bent terminal end of item 6. 3. Select and install proper insulators as shown. 4. Mark and install circuit number identification band and part number identification band using old cable as reference. Figure D-39. Battery Cable Assembly INSULATOR BOOT CABLE PART NUMBER IDENTIFICATION BAND TERMINAL INSULATOR CIRCUIT NUMBER IDENTIFICATION BAND