TM 9-2320-280-20-3 Change 2 D-23 Section II. ILLUSTRATED MANUFACTURING INSTRUCTIONS (Cont'd) WINCH BATTERY CABLE CABLE CUT ITEM PART LENGTH MANUFACTURED END TERMINALS END INSULATOR NO. NUMBER (INCHES) FROM NSN NSN 1 15847 74 6145-00-538-8219 5940-00-520-2447 M23053/03-0 5940-00-197-3664 (81349) 2 15848 87-1/2 6145-00-538-8219 5940-00-520-2447 M23053/03-0 5940-00-197-3664 (81349) INSTRUCTIONS: 1. Determine cable number needed from RPSTL and cut cable 6145-00-538-8219 to length as shown. 2. Select and solder proper end terminals to cable ends as shown. (Refer to TC 9-237 for soldering instructions.) 3. Install insulator as shown. 4. Cut 14 inches of spiral wrap from bulk 25 FT 2661-8P (98441) and install as shown. Spiral wrap is held in position with black tape at both ends. 5. Mark and install identification band using old cable as reference. Figure D-38. Winch Battery Cable MATERIAL BLOCK STOCK SIZE DESCRIPTION SPECIFICATION 4 IN. GAGE, TYPE 1, CLASS A WIRE, ELECTRICAL MIL-C-13486 2 ± 0.25 IN. 12 ± 0.25 IN. 14 ± 0.25 IN. INSULATOR IDENTIFICATION BAND SPIRAL WRAP BLACK TAPE TERMINAL 5904-00-520-2447 TERMINAL 5940-00-197-3664