TM-9-2320-280-20 HMMWV Technical Manual Unit Maintenance Volume 3 Download

Page 527 of 1170

11-181. AMBULATORY PATIENT SEAT REPLACEMENT This task covers: a. Removal b. Installation NOTE For instructions on replacement of rivets, refer to para. 10-66. 1. Remove two screws (6) from seat brace (2) and seat frame (1). 2. Remove two locknuts (5), screws (3), and seat brace (2) from seatback (4). Discard locknuts (5). 3. Inspect blind rivnut (7) for damage. Replace if damaged. 4. Remove four blind rivets (12) and seat support (8) from seatback (4). 5. Remove two solid rivets (11), latch (9), and shim (10) from seat support (8). a. Removal INITIAL SETUP: Applicable Models M996, M996A1 Tools General mechanic’s tool kit: automotive (Appendix B, Item 1) Materials/Parts Four blind rivets (Appendix G, Item 252) Two locknuts (Appendix G, Item 70) Two solid rivets (Appendix G, Item 271) Blind rivnut (Appendix G, Item 274) Manual References TM 9-2320-280-10 TM 9-2320-280-24P Equipment Condition Ambulatory patient seat opened (TM 9-2320-280-10). TM 9-2320-280-20-3 Change 2 11-263 1 7 2 3 4 5 6 8 9 10 4 12 11