TM-9-2320-280-20 HMMWV Technical Manual Unit Maintenance Volume 3 Download

Page 1069 of 1170

TM 9-2320-280-20-3 D-96 Change 1 Figure D-109. Tip Jack Lead Assembly. MATERIAL BLOCK STOCK SIZE DESCRIPTION SPECIFICATION 14 AWG WIRE, ELECTRICAL MIL-C-13486/1 N/A INSULATION SLEEVING MIL-I-23053/5 Section II. ILLUSTRATED MANUFACTURING INSTRUCTIONS (Cont'd) INSTRUCTIONS: NOTE When connecting electrical wire to receptacle pins on tip jacks, use NSN 3493-00-133-1108 solder. (Refer to TB SIG-222 for soldering.) 1. Cut wire (1) into five 12-in. sections as shown. 2. Cut insulation sleeving (3) into five 1-in. sections as shown. 3. Connect five wires (1) to receptacle pins on tip jacks (2). 4. Place insulation sleeving (3) over wires (1) and receptacle pins and heat-shrink insulation sleeving (3) into position. ITEM MATERIALS NO. REQ’D DESCRIPTION NSN 1 5 Electrical Wire: 12 in. 6145-00-152-6499 2 5 Tip Jack 5935-00-683-7651 3 5 Insulation Sleeving: 1 in. 5970-00-815-1295