TM-9-2320-280-20 HMMWV Technical Manual Unit Maintenance Volume 2 Download
Page 64 of 953
TM 9-2320-280-20-2  3-44 Change 2  3-24. FUEL TANK MAINTENANCE (Cont'd)  d. Cleaning and Inspection  ________  WARNING  ________  Drycleaning solvent is flammable and will not be used near an open  flame. A fire extinguisher will be kept nearby when the solvent is  used. Use only in well-ventilated places. Failure to do this may  result in injury to personnel or damage to equipment.  1. Use drycleaning solvent to clean access cover (3), fuel supply line (11), fuel return line (10), arctic  heater fuel supply line (9), fuel supply tube (4), fuel return tube (13), arctic heater fuel supply  tube (5), and inside fuel tank (7).  2. Inspect access cover (3), fuel supply line (11), fuel return line (10), fuel supply tube (4), fuel return  tube (13), strainer (6), tee (8), fitting (12), vent line housing (2), and grommet (1) for cracks, wear,  and breaks. Replace if cracked, worn, or broken.  3. Inspect arctic heater fuel supply line (9) and arctic heater fuel supply tube (5) for cracks, wear, and  breaks, if installed. Replace if cracked, worn, or broken.  4. Inspect sending unit (14) for damage. Replace if damaged.