TM-9-2320-280-20 HMMWV Technical Manual Unit Maintenance Volume 2 Download

Page 613 of 953

5-18. SEALED UPPER CONVERTER HOUSING COVER (2-PIECE) MAINTENANCE 1. Inspect converter housing cover (4) for pitting, cracking, and excessive wear. Replace if pitted, cracked, or excessively worn. 2. Remove gasket material and sealant from converter housing cover (4) and transmission (1) with drycleaning solvent. This task covers: a. Removal c. Installation b. Inspection a. Removal 1. Remove two capscrews (3) and converter housing cover (4) from transmission (1) . 2. Remove gasket (5) from converter housing cover (4). Discard gasket (5). c. Installation 2. Apply adhesive to converter housing cover edge (5) and install converter housing cover (4) on transmission (1) with two capscrews (3). 3. Apply adhesive to fill any gaps between housing cover (4). INITIAL SETUP Tools General mechanic’s tool kit: automotive (Appendix B, Item 1) Materials/Parts Gasket (Appendix G, Item 44) Adhesive (Appendix C, Item 5) Drycleaning solvent (Appendix C, Item 18) Manual References TM 9-2320-280-24P Equipment Condition Battery ground cable disconnected (para. 4-73). General Safety Instructions Drycleaning solvent is flammable and will not be used near an open flame. b. Inspection WARNING Drycleaning solvent is flammable and will not be used near an open flame. A fire extinguisher will be kept nearby when the solvent is used. Use only in well-ventilated places. Failure to do this may result in injury to personnel and/or damage to equipment. 1. Apply adhesive to gasket (5) and install on converter housing cover (3). NOTE Gasket may require bending over edge of converter housing cover to make gasket seat properly. TM 9-2320-280-20-2 5-42 Change 3