TM-9-2320-280-20 HMMWV Technical Manual Unit Maintenance Volume 2 Download

Page 472 of 953

TM 9-2320-280-20-2 4-104. RESUSCITATOR/ASPIRATOR CABLE REPLACEMENT This task covers: a. Removal b. Installation INITIAL SETUP: Applicable Models Manual References M996, M996A1, M997, M997A1, M997A2 TM 9-2320-280-24P Tools General mechanic’s tool kit: automotive (Appendix B, Item 1) NOTE Replacement of resuscitator/aspirator cable is basically the same for M996, M996A1, M997, M997A1, and M997A2 vehicles. This procedure covers M997, M997A1, and M997A2 vehicles. For instructions on replacement of rivets, refer to para. 10-66. a. Removal 1. Remove two screws (3), clamps (7), and cable (1) from body (2) and floor (6). 2. Remove nine rivets (4) from cable duct (5) and floor (6) and slide duct (5) left to remove. 3. Remove two screws (9), clamps (10), cable (1), and power harness clamp (8) from body (2). 4. Remove grommet (11) from floor (6) and remove cable (1) through hole in floor (6). 1. Install grommet (11) in floor (6). 2. Route cable (1) through grommet (11) in floor (6) and position in approximate mounting location. 3. Connect cable (1) to resuscitator and power source. (Leave slack at each end of cable before clamping to connect resuscitation equipment if not installed.) 4. Install two clamps (7) and cable (1) on body (2) and floor (6) with two screws (3). 5. Install cable duct (5) over cable (1) and slide to right under heat duct to mounting position. 6. Install cable duct (5) on floor (6) with nine rivets (4). 7. Install two clamps (10), cable (1), and power harness clamp (8) on body (2) with two screws (9). 4-234