TM-9-2320-280-20 HMMWV Technical Manual Unit Maintenance Volume 1 Download
Page 849 of 890
TM 9-2320-280-20-1  RESISTANCE AND CONTINUITY O TO 4500 OHMS TEST #91  Description:  This procedure measures resistance in the range  of 0 to 4500 ohms. The VTM is used as an ohm-  meter, and test results are always displayed with  the decimal point in the right position. Additionally,  any voltage present in the device being tested will  adversely affect test results. Make sure the circuit  or component being tested is shut off. Test re-  quires the use of the TK adapters and transducers.  Typical Applications:  ● Continuity checks  ● Resistance measurements  ● Switch and relay functions  Test Procedure:  1. Connect test probe cable W2. Attach P1 to J4.  2. Connect the desired test leads to P2.  3. Set TEST SELECT switch to 91.  4. Short leads together. Press and hold TEST  button until CAL appears on display.  5. Release TEST button and wait for offset value to  appear on display.  6. If offset is within -225 to 225 proceed. If no go  to DCA Troubleshooting Procedure  7. Press and release TEST button. Observe  displayed value.  Pre-Test Procedures  Run Confidence Test.  Control Functions:  01,02,03,04,06  Possible Error Messages  E005 Offset not Performed.  E022 External voltage  detected while  measuring resistance.  2-752