TM-9-2320-280-20 HMMWV Technical Manual Unit Maintenance Volume 1 Download

Page 423 of 890

1 2 3 4 5 6 Glowplug Controller Harness with sockets 3 & 6 highlighted TM 9-2320-280-20-1 REFERENCE INFORMATION Change 1 2-318.13 GLOWPLUGS CONTINUITY (RESISTANCE) MULTIMETER 1. Set the voltmeter to an ohms scale of about 1000 ohms. 2. Connect the RED and BLACK leads to the connections stated in the question. 3. Be sure to read the correct scale. Less than 5 ohms indicates continuity. For an open circuit, the meter should peg full scale (needle all the way to the left). A B C D E F G H I Engine Connector Harness with sockets “A” & “B” highlighted. 0-4500 OHMS STE/ICE-R TEST 91 1. Connect RED clip and BLACK clip to the indicated test points in the question. RED to the first, BLACK to the second. 2. Start Test 91, 0-4500 ohms. 3. Displayed reading is in ohms. Less than 5 ohms is continuity. If the resistance is over 4500 ohms, STE/ICE displays '9.9.9.9.' Disconnect negative battery cable before disconnecting and reconnecting distribution box harness. There is battery voltage at the distribution box at all times. Failure to disconnect battery cable will result in damage to equipment or injury to personnel. WARNING 1 2 3 4 5 6 Glowplug Controller