TM-9-2320-280-20 HMMWV Technical Manual Unit Maintenance Volume 1 Download
Page 410 of 890
TM 9-2320-280-20-1 REFERENCE INFORMATION WARNING Disconnect negative battery cable before disconnecting and reconnecting protective control box harness. There is battery voltage at the PCB at all times. Failure to disconnect battery cable will result m damage to equipment or injury to personnel. Repair wiring or replace harness, refer to (pare 4-34). Repair wiring or replace harness, refer to (para 4-85). Replace glowplug controller, refer to (para 4-29). GLOWPLUGS CIRCUIT 0-4500 OHMS STE/ICE-R TEST 91 1. Connect RED clip and BLACK clip to the indicated test points in the question. RED to the first, BLACK to the second. 2. Start Test 91,0-4500 ohms. 3. Displayed reading is in ohms. Less than 5 ohms is continuity. If the resistance is over 4500 ohms, STE/lCE displays "9.9.9.9." CONTINUITY (RESISTANCE) Multimeter 1. Set the voltmeter to an ohms scale of about 1000 ohms. 2. Connect the RED and BLACK leads to the connections stated in the question. 3. Be sure to read the correct scale. Less than 5 ohms indicates continuity. For an open circuit, the meter should peg full scale (needle all the way to the left). 2-317/(2-318 Blank)