TM-9-2320-280-20 HMMWV Technical Manual Unit Maintenance Volume 1 Download
Page 389 of 890
WARNING TM 9-2320-280-20-1 REFERENCE INFORMATION Change 1 2-295 0-4500 OHMS STE/ICE-R TEST 91 1. Connect RED clip and BLACK clip to the terminals indicated in the question. 2. Start Test 91, 0-4500 ohms. 3. Displayed reading is in ohms. Less than 5 ohms is continuity. If the resistance is over 4500 ohms, STE/ICE-R displays “9.9.9.9.” CONTINUITY (RESISTANCE) MULTIMETER 1. Set the voltmeter to an ohms scale of about 1000 ohms. 2. Connect the RED and BLACK leads to the connections stated in the question. 3. Be sure to read the correct scale. Less than 5 ohms indicates continuity. For an open circuit, the meter should peg full scale (needle all the way to the left). STARTER CIRCUIT Replace PCB, refer to (para. 4-5). Replace distribution box, refer to (para. 4-5.1). Disconnect negative battery cable before disconnecting and reconnecting protective control box/distribution box harness. There is battery voltage at the PCB/distribution box at all times. Failure to disconnect battery cable will result in damage to equipment or injury to personnel.