TM 9-2320-280-20-1  REFERENCE INFORMATION  Change 1 2-291  VOLTAGE  MULTIMETER  1. Set the voltmeter to a DC volts scale of at least  40 volts.  2. Connect the RED lead to positive and the  BLACK lead to negative.  3. Be sure to read the correct scale.  CONTINUITY (RESISTANCE)  MULTIMETER  1. Set the voltmeter to an ohms scale of about  1000 ohms.  2. Connect the RED and BLACK leads to the  connections stated in the question.  3. Be sure to read the correct scale. Less than 5  ohms indicates continuity. For an open circuit,  the meter should peg full scale (needle all the  way to the left).  STARTER CIRCUIT  Replace rotary switch, refer to (para. 4-7).  Repair wiring or replace switch, refer to  (para. 4-7).  A  B  C D  E  F  G  H  PCB/DISTRIBUTION BOX BODY CONNECTOR  The connections for the neutral safety  switch can be reached by removing the  engine cover. The connections are near  the gear shift lever.  0-4500 OHMS  STE/ICE-R TEST 91  1. Connect RED clip and BLACK clip to the  terminations indicated in the question. RED to  the first, BLACK to the second.  2. Start Test 91, 0-4500 ohms.  3. Displayed reading is in ohms. Less than 5  ohms is continuity. If the resistance is over 4500  ohms, STE/ICE displays “9.9.9.9.”  0-45 DC VOLTS  STE/ICE-R TEST 89  1. Connect RED clip to the indicated test  point, BLACK clip to negative or ground.  2. Start Test 89, DC volts.  3. Displayed reading is in volts.  Disconnect negative battery cable before  disconnecting and reconnecting protective  control box/distribution box harness.  There is battery voltage at the PCB/distribution  box at all times. Failure to disconnect battery  cable will result in damage to equipment or  injury to personnel.  WARNING