TM-9-2320-280-20 HMMWV Technical Manual Unit Maintenance Volume 1 Download
Page 352 of 890
REFERENCE INFORMATION  TM 9-2320-280-20-1  BATTERY CIRCUIT  Measure from the positive poet to the  negative poet of each battery.  For battery replacement instructions,  refer to (para. 4-79).  NOTE  Check these cables:  WIRE 68, connecting the batteries  together. Test point is the postive  terminal of one of the batteries.  WIRE 49A, connecting the batteries  to the power stud. Test point is the  power stud.  Wire connecting the battery to the  shunt. Test point is the shunt.  Wire connecting shunt to ground  stud. Test point is the shunt.  For repair or replacement of cables,  refer to (para. 4-73).  If you use STE/lCE-R test 67 in Step  3 on page 2-252, you may have a  faulty DCA. Try running the tests  using STE/lCE-R test 89 with the  W2 cable.  Sea paragraph 4-79. (Also check each  battery's specific gravity in accordance  with TM 9-6140-200-14.)  0-45 DC VOLTS  STE/lCE-R TEST 89  1. Connect RED clip to the indicated test point,  BLACK cIip to negative or ground.  2. Start Test 89, DC volts.  3. Displayed reading is in volts.  Replace battery refer to (para. 4-79).  2-257