TM-9-2320-280-20 HMMWV Technical Manual Unit Maintenance Volume 1 Download
Page 315 of 890
TM 9-2320-280-20-1  ALTERNATOR  2-224.6 Change 1  C  DIAGNOSTIC FLOWCHART  G  FROM B1,  Page 2-204  REPLACE REGULATOR  (Para 4-5.10). THEN GO TO 5,  Page 2-198  KNOWN INFO  POSSIBLE PROBLEMS  WIRING  ALTERNATOR  REGULATOR  VOLTAGE OUTPUT  INCORRECT  TEST OPTIONS  REASON FOR QUESTION  STE/ICE-R TEST 10,  (interleave with control function  01 of page 2-734 then 89,  page 2-750)  Determine if high or low output  voltage.  G2  START ENGINE AND ALLOW TO IDLE  AT 1200-1500 RPM FOR 2-3 MINUTES.  RECHECK VOLTAGE OUTPUT.  IS ALTERNATOR OUTPUT LESS THAN  26 VOLTS?  YES  IF OUTPUT VOLTAGE  IS OVER 30.5 VOLTS,  REPLACE  REGULATOR  (Para 4-5.10)  NO  TEST OPTIONS  REASON FOR QUESTION  Visual  Must know model of alternator to  perform proper tests.  NO  SEE NOTE ON  OPPOSITE PAGE  G1  IS THIS A NIEHOFF 200 AMP DUAL  VOLTAGE ALTERNATOR?  YES  KNOWN INFO  POSSIBLE PROBLEMS  ALTERNATOR  REGULATOR  VOLTAGE OUTPUT  INCORRECT  REGULATOR HAS  ENERGIZING VOLTAGE  TEST OPTIONS  REASON FOR QUESTION  STE/ICE-R TEST 10 AND 90  (pages 2-734 and 2-751)  This connection applies full  current loading to field coil.  Alternator current output should  be near maximum.  G3  DISCONNECT ALTERNATOR-  TO-REGULATOR CABLE. START  ENGINE AND SET IDLE 1200-1500 RPM.  USING 15-AMP CAPACITY JUMPER  WIRE, MOMENTARILY CONNECT PIN A  OF ALTERNATOR CONNECTOR TO  ENGINE GROUND. DOES CURRENT  AND VOLTAGE RISE DURING  CONNECTION?  YES  REPLACE ALTERNATOR  (Para 4-5.7). THEN GO TO  5, Page 2-198  NO