TM-9-2320-280-20 HMMWV Technical Manual Unit Maintenance Volume 1 Download
Page 106 of 890
Table 2-1. Unit Level Preventive Maintenance Checks and Services HMMWV (Cont'd)  ITEM  NO.  INTERVAL  ITEM TO BE  INSPECTED  PROCEDURES  13 Semi- Starter  Annual  a. Inspect starter for mounting a. Mounting bolt  security. Tighten mounting bolts to missing or will not  40 lb-ft (54 N  •  m). torque.  b. Inspect cables and studs for loose b. Stud nut loose.  nuts and damage.  13.1 Semi- Neutral  Annual Start Safety  Switch  a. Disconnect wires 14A and 14B from Neutral start safety  wires 14 at neutral start safety switch is malfunctioning.  switch.  b. Check for continuity of neutral  start safety switch.  (1) With transmission shift lever in  N (neutral), or P (park) (for M1123,  A2 series, and up-armor models only),  continuity should be present between  wires 14 at neutral start safety  switch.  TM 9-2320-280-20-1  Change 1 2-15  NOT FULLY MISSION  CAPABLE IF:  CAUTION  Disconnect negative cable.  12 Semi- Engine and c. Using 3/4 inch torque adapter c. Transmission mount  Annual Trans- (reefer to Appendix B, Item 145), loose, cracked, or  mission tighten two capscrews securing damaged.  Mount transmission mount to adapter to  (Cont’d) 65 lb-ft (88 N  •  m). Tighten two locknuts  securing transmission mount to  crossmember to 28 lb-ft (38 N  •  m).  WARNING  Ensure vehicle parking brake is set,  wheels are chocked, and rotary  switch is in the ENG STOP position.  Failure to comply may result in  injury to personnel and/or damage to  equipment.