TM-10-5411-205-13 HMMWV S-250/G Shelter Operator, Unit and Direct Support Download

Page 15 of 127

TM 10-5411-205-13 2-3. Explanation of columns (cont). d. Equipment is Not Ready/Available If. This column tells you when and why your equipment cannot be used. Item 1 2 3 4 NOTE Perform your “weekly checks” in addition to the “before checks” if you are the assigned operator and have not operated the equipment since the last weekly check was performed, or if you are operating the equipment for the frost time. Table 2-1. Operator Preventive Maintenance Checks and Services. NOTE Within designated interval, these checks are to be performed in the order listed. Item to be Inspected Door Handles Louver Cover Assembly (Inner Door) Door Stay Assemblies Door Assemblies, Inner and Outer Procedures Check for and have repaired or adjusted as necessary Make sure handles on inner and outer doors operate smooth ly without binding or jamming. a. Make sure louver cover assembly can be held in the open position. b. Make sure weather gasket is in good condition. c. Make sure air filter, louvers and directional vanes are not blocked. Make sure that each door stay assembly rod slides smoothly in channel and rotates easily in bracket. Check for loose or missing hardware or detent pin a. Make sure doors open and close smoothly without binding Check hinges for loose loose or missing hardware. Lubri- cate hinges. b. Make sure rain flap above louver cover assembly is intact. Item is Not Ready/ Available if Door cannot be opened or cannot be closed securely. a. Louver cover assembly cannot be held open. c. Air filters, louvers or vanes are blocked. a. Door cannot be opened or cannot be closed securely. 2-2