Page 11 of 127

TM 10-5411-205-13 1-9. Location and Description of Major Components. (Figure 1-1) 1. 2. 3. 4. ITEM DESCRIPTION Door assembly Provides personnel access to interior of shelter. Inner (emergency) door assembly Provides emergency personnel exit and allows fresh air to enter shelter through an air vent with filter. The shielded shelters are provided with an RFI/EMI filter. Lifting bracket assembly Provides hookup point for sling assembly when lifting shelter and when securing shelter onto truck. Towing bracket assembly Provides hookup point for guide rope when guiding sling- lifted shelter into position and when securing shelter onto 5. Recessed step pan assembly 6. Skid assemblies truck. Allows access to roof. Permit a fully equipped shelter to be seated on rough terrain. They also provide forklifting access. Figure 1-1. Major Shelter Components. 1-10. Equipment Data. Height Width Length Gross weight Cubage Load on skids 70.125 in (178.11 cm) 79.0625 in (200.82 cm) 86.625 in (220.03 cm) Shield 770 lb (349 kg) empty Unshielded 782 lb (355 kg) fully loaded Empty 1.8 psi Fully loaded 6.2 psi Change 1 1-3