TM 10-5411-205-13 3-24. Louver Assembly, Holder Assembly and RFI/EMI Filter (cont). d. Install. (Figure 3-26) (1) (2) (3) (4) (5) (6) (7) . Apply sealer to both ends of top flange of shield (19). Position RFI/EMI filter (20), shield (19), and frame (18) in place into inner door assembly (14), and secure with seven phillips head screws (15), nuts (16), and lock washers (17). Apply silicone sealer on mounting surface of gasket (13) and insert gasket (13) and louver assembly (12) into frame assembly (11). Position frame assembly (11) in place against RFI/EMI falter (20) and secure with 31 phillips head screws (8), nuts (9), and lock washers (10). Position each end of holder (6) into bracket assemblies (7) and secure with groove pins (5). Position holder assembly (4) in place over frame assembly (11) and secure with four phillips head screws (1), nuts (2), and lock washers (3). Apply a continuous bead of sealer around mounting edges of frame (18) and frame assembly (11). 3-49