TM-10-5411-205-13 HMMWV S-250/G Shelter Operator, Unit and Direct Support Download
Page 52 of 127
TM 10-5411-205-13 3-18. Door Gaskets (cont). (c) Repeat the seal pressure test of paragraph 3-18.b. If the seal pressure remains insufficient, add another 0.032 inch shim. (d) Repeat this process until sufficient seal pressure is developed or until the maximum allowable thickness is obtained. d. Replace. (Figure 3-20) To replace the RFI/EMI gasket (13), remove gasket from track and clean track of any dirt. Place new gasket over track and snap in place. To replace the silicone weather gasket (14), proceed as follows (1) Remove gasket (14) and clean track from adhesive residue. (2) Apply sealer in track groove all around door and snap new gasket in place in track on door. CAUTION Allow at least 30 minutes cure time for adhesive before using door. Figure 3-19. Typical Locations for Door Gasket Testing. 3-35