TM 10-5411-205-13 3-9. General Repair (1) Installation. Procedures (cont). (Figure 3-6) NOTE When installing new rivet in same location as a rivet that has been removed and if diameter of hole in structure has been enlarged during removal of rivet, use next larger diameter rivet for replacement. Clean rivets with solvent before installing. PROPER INSTALLATION IMPROPER INSTALLATION Figure 3-6. Installing Blind Rivets. (a) Determine type, size and grip range of rivet to be used. Grip length equals combined thickness of materials being riveted together. Grip range of rivet must encompass grip length. Drilling creates metal chips which may enter eyes and cause seri- ous injury. Eye protection is required. CAUTION Do not drill deeper than necessary to through other side of panel. NOTE install rivet as you may drill Drill hole size must match size of rivet being used. Quantities of sheets maybe drilled at the same time when held together with sheet fasteners. 3-14