2-69 TB 9 -2510-251-13 2-1.2 Installation of Air Conditioning Kit to M1097A2 with GSIE Add-on-Armor (Cont’d). d. Install Refrigerant Hoses (Cont’d) Figure 2-103. Condenser Connection (15) Connect Condenser. a. Four-door vehicles only: Lubricate O-ring and install #6 female straight fitting on outlet (smaller) fitting on condenser. b. Two-door vehicles only: Lubricate O-ring and install #6 female 45° fitting (20) on outlet (smaller) fitting on condenser. c. Lubricate O-ring and install #8 female straight fitting (21) to inlet (larger) fitting on condenser. d. Trim ends of #6 hose (22) from drier and connect to right fitting. e. Trim ends of #8 hose (23) from compressor and connect to left fitting. (16) Reinstall plywood panel on top of transmission tunnel by notching around drain hoses and refrigerant lines. 21 22 20 23