TB-9-2510-251-13 HMMWV Operator and Field Maintenance, Installation & Parts Add-On-Armor Air Conditioning Download
Page 84 of 624
2-68 TB 9-2510-251-13 2-1.2 Installation of Air Conditioning Kit to M1097A2 with GSIE Add-on-Armor (Cont’d). d. Install Refrigerant Hoses (Cont’d) 17 18 16 19 Figure 2-102. Drier Connection (14) Connect Drier. a. Lubricate O-ring and install #6 male stainless tube (16) on drier outlet. b. Lubricate O-ring and install #6 female 90° fitting (17) on drier inlet. c. Trim ends of #6 hose (18) to condenser and connect to inlet (female) fitting. d. Trim ends of #6 hose (19) to evaporator and connect to outlet (male) fitting. e. Tighten fittings.