TB-9-2510-251-13 HMMWV Operator and Field Maintenance, Installation & Parts Add-On-Armor Air Conditioning Download

Page 56 of 624

2-40 TB 9-2510-251-13 2-1.2 Installation of Air Conditioning Kit to M1097A2 with GSIE Add-on-Armor (Con't). a. Install Compressor (Cont’d) Figure 2-57. Compressor Installation 19 21 22 18 20 (15) Position compressor (18) on mounting bracket (19) and secure with screw (20), washer (21), and locknut (22). Tighten bolt to 18 ft-lbs. Do not overtighten.