2-39 TB 9 -2510-251-13 2-1.2 Installation of Air Conditioning Kit to M1097A2 with GSIE Add-on-Armor (Cont’d). a. Install Compressor (Cont’d) 15 Figure 2-55. Ground Cables Disconnect 14 14 15 Figure 2-56. Air Intake Duct Support Bracket (12) Disconnect ground cables (14) from lower cylinder head stud. Set aside hardware. (13) Remove bolts/studs (15), attaching air intake duct support bracket (16) and fuel line clamps to engine. (14) Disconnect fuel return hose from fuel return line “T” (17) 17 16