TB-9-2510-251-13 HMMWV Operator and Field Maintenance, Installation & Parts Add-On-Armor Air Conditioning Download
Page 45 of 624
2-29 TB 9-2510-251-13 21 22 20 23 2-1.1 Installation of Air Conditioning Kit to M998 and M998A1; M1037; M1097 and M1097A1 with GSIE Add-on-Armor (Cont’d). d. Install Refrigerant Hoses (Cont’d) Figure 2-39. Condenser Connection (15) Connect Condenser. a. Four-door vehicles only: Lubricate O-ring and install #6 female straight fitting on outlet (smaller) fitting on condenser. b. Two-door vehicles only: Lubricate O-ring and install #6 female 45° fitting (20) on outlet (smaller) fitting on condenser. c. Lubricate O-ring and install #8 female straight fitting (21) to inlet (larger) fitting on condenser. d. Trim ends of #6 hose (22) from drier and connect to right fitting. e. Trim ends of #8 hose (23) from compressor and connect to left fitting. (16) Reinstall plywood panel on top of transmission tunnel by notching around drain hoses and refrigerant lines.