TB-9-2510-251-13 HMMWV Operator and Field Maintenance, Installation & Parts Add-On-Armor Air Conditioning Download
Page 257 of 624
2-241 TB 9-2510-251-13 Section III. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) 2-3 General. Table 2-1 (Operator PMCS Table) has been provided so you can keep your equipment in good operating condition and ready for its primary mission. 2-3.1 Warnings, Cautions, and Notes. Always observe the WARNINGS, CAUTIONS, and NOTES appearing in your PMCS table. Warnings and Cautions appear before applicable procedures. You must observe WARNINGS to prevent serious injury to yourself and to others. You must observe CAUTIONS to prevent your equipment from being damaged. You must observe NOTES to ensure procedures are performed properly. 2-3.2 Explanation of Table Entries: 2-3.2.1 Item No. Column. Numbers in this column are for reference. When completing DA Form 2404 (Appendix A) or computerized DD Form 5988E (Appendix A), include the item number for the checks/service indicating a fault. Item numbers also appear in the order that you must do checks and services for the intervals listed. 2-3.2.2 Interval Column. This column tells you when you must do the procedure in the procedure column. “BEFORE” procedures must be done before you operate the HMMWV with Air Conditioning Kit installed for its intended mission. “DURING” procedures must be done during the time you are operating the air conditioner for its intended mission. “AFTER” procedures must be done immediately after shutting down the air conditioner. Perform “WEEKLY” procedures at the listed interval. 2-3.2.3 Location, Item to Check/Service Column. This column lists the location and the item to be checked or serviced. The item location is underlined. 2-3.2.4 Procedure Column. This column gives the procedure for checking or servicing the item listed in the location, item to check/service column. You must perform the procedure to know if the air conditioner is ready or available for its intended mission or operation. You must do the procedure at the time stated in the interval column. 2-3.2.5 Not Fully Mission Capable if: Column. Information in this column tells you what faults will keep your air conditioner from being capable of performing its primary mission. If you make checks or services that show faults listed in this column, do not operate the air conditioner. 2-3.2.6 Reporting and Correcting Deficiencies. If Air Conditioning Kit does not perform as required, refer to Chapter 3, Operator Maintenance, Section I, Operator Troubleshooting Procedures. 2-3.3 Other Table Entries. Be sure to observe all special information and notes that appear in your table.