TB-9-2510-251-13 HMMWV Operator and Field Maintenance, Installation & Parts Add-On-Armor Air Conditioning Download
Page 254 of 624
2-238 TB 9-2510-251-13 2-2.3 Installation of Air Conditioning Kit to M1097A2 Two-Door with O'Gara Hess Add-on-Armor (Cont’d). g. Air Distribution Ducting (Cont’d) (2) Cut enough flex hose (9) to connect elbow (1) and elbow (8). (3) Pre-bend band clamp and flex hose into 2.5 inch square. (4) Attach flex hose (9) to elbow (1) and elbow (8) with band clamp (10). (5) When air delivery is acceptable, apply a generous quantity of PVC cement (item 3, Appendix D) to the mating surfaces and secure with screws. 10 8 10 9 1 Figure 2-344. Flex Hose