TB-9-2510-251-13 HMMWV Operator and Field Maintenance, Installation & Parts Add-On-Armor Air Conditioning Download

Page 249 of 624

2-233 TB 9-2510-251-13 2-2.3 Installation of Air Conditioning Kit to M1097A2 Two-Door with O'Gara Hess Add-on-Armor (Cont’d). d. Install Refrigerant Hoses (Cont’d) (14) Connect Condenser. a. Four-door vehicles only: Lubricate O-ring and install #6 female straight fitting on outlet (smaller) fitting on condenser. b. Two-door vehicles only: Lubricate O-ring and install #6 female 45° fitting (22) on outlet (smaller) fitting on condenser. c. Lubricate O-ring and install #8 female straight fitting (23) to inlet (larger) fitting on condenser. d. Trim ends of #6 hose (24) from drier and connect to right fitting. e. Trim ends of #8 hose (25) from compressor and connect to left fitting. f. Reinstall plywood panel on top of transmission tunnel by notching around drain hoses and refrigerant lines. (15) Reinstall plywood panel on top of transmission tunnel by notching around drain hoses and refrigerant lines. 23 24 22 25 Figure 2-236. Condenser Connection