TB-9-2510-251-13 HMMWV Operator and Field Maintenance, Installation & Parts Add-On-Armor Air Conditioning Download

Page 240 of 624

2-224 TB 9-2510-251-13 (25) Pull rear curtain down tight over rear of armor plate. (26) Mark and cut four crosses (8) over the bolts and nuts attaching the center armor plate to the rear side plates. (27) Cut crosses just large enough for nut to push through. 8 2-2.3 Installation of Air Conditioning Kit to M1097A2 Two-Door with O'Gara Hess Add-on-Armor (Cont’d). b. Install Evaporator and Condenser (Cont’d) Figure 2-328. Center Armor Hardware Cutouts