TB-9-2510-251-13 HMMWV Operator and Field Maintenance, Installation & Parts Add-On-Armor Air Conditioning Download

Page 218 of 624

2-202 TB 9-2510-251-13 AIR INTAKE DUCT 1 2-2.3 Installation of Air Conditioning Kit to M1097A2 Two-Door with O'Gara Hess Add-on-Armor (Cont’d). a. Install Compressor CAUTION When tightening bolts, DO NOT overtighten. Torque to specified torque value only. Failure to comply may result in damage to equipment. NOTE The Compressor Kit is designed to be installed with both versions of the liten serpentine belt drive systems. Compressor Mounting Model RD-9-10012-0: Figure 2-291. Breaker Bar Figure 2-292. Air Intake Duct Removal (1) Using a 3/8 ratchet or breaker bar, rotate belt tensioner (1). Slip belt off passenger side grooved idler pulley. Remove belt. (2) Mark air intake duct at the air filter housing. Remove air intake duct.