2-193 TB 9-2510-251-13 19 20 18 21 2-2.2 Installation of Air Conditioning Kit to M998 and M998A1 Four-Door with O'Gara Hess Add-on-Armor (Cont’d). d. Install Refrigerant Hoses (Cont’d) Figure 2-278. Drier Connection (13) Connect Drier. a. Lubricate O-ring and install #6 male stainless tube (18) on drier outlet. b. Lubricate O-ring and install #6 female 90° fitting (19) on drier inlet. c. Trim ends of #6 hose (20) to condenser and connect to inlet (female) fitting. d. Trim ends of #6 hose (21) to evaporator and connect to outlet (male) fitting. e. Tighten fittings.