TB-9-2510-251-13 HMMWV Operator and Field Maintenance, Installation & Parts Add-On-Armor Air Conditioning Download

Page 204 of 624

2-188 TB 9-2510-251-13 2-2.2 Installation of Air Conditioning Kit to M998 and M998A1 Four-Door with O'Gara Hess Add-on-Armor (Cont’d). d. Install Refrigerant Hoses (Cont’d) CAUTION Avoid high heat surfaces, sharp edges, and moving parts of vehicle. Keep hoses tucked up high enough to prevent being snagged as vehicle travels over obstacles or brush. Failure to comply may result in damage to equipment. Hoses should span no more than two feet without being secured. Failure to comply may result in damage to equipment. Figure 2-273. P-Clamp 2 4 HIDDEN 1 3 HIDDEN (7) Drill a 5/16 inch (.312) diameter hole in lower flange of fender well and secure #8 and #12 hoses with bolt (1), p-clamp (2), washer (3), and locknut (4).